ORIGINAL ARTICLE
Year : 2019  |  Volume : 3  |  Issue : 2  |  Page : 293-296

Comparison of measurements of the axial length of the eye using partial coherence interferometry and applanation ultrasound


Department of Ophthalmology, Faculty of Medicine for Girls, Al-Azhar University, Cairo, Egypt

Correspondence Address:
MD Rehab M Kamel
17 Abd Al-Hakem Al-Rifai Street, Nasr City, Cairo, 11765
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/sjamf.sjamf_5_19

Get Permissions

Introduction Accurate biometry is an essential component of cataract surgery. Preoperative measurement of axial eye length (AEL), rather than the corneal curvature, is the most critical factor for accurate calculation of the intraocular lens (IOL) power [1]. Aim The aim of this study was to compare axial eye length (AEL) measured by applanation ultrasound (U/S) biometry versus that measured by partial coherence interferometry in eyes with clear crystalline lenses and eyes with cataract. Patients and methods A prospective, nonrandomized study included 60 eyes which were divided into two groups. Group I: 30 eyes with clear crystalline lenses. Group II: 30 eyes with cataractous lenses. Each group is further subdivided into three groups: group a with short AEL (<22.00 mm), group b with average AEL (22.00–25.00 mm), and group c with long AEL (>25 mm). Complete ophthalmological examination was performed for every patient. AEL was assessed by applanation A-scan U/S and optical biometry using partial coherence interferometry. Results A total of 60 eyes were included in the study. In group I (clear crystalline lens group), the mean AEL by applantion U/S biometry was 24.23±3.73 mm which is shorter than the mean AEL measured by optical biometry which is 24.48±3.66 mm and the difference is statistically highly significant (P=0.002). In group II (cataractous lens group), the mean AEL by applantion U/S biometry was 24.27±3.57 mm which is shorter than the mean AEL measured by optical biometry which is 24.46±3.43 mm and the difference between the two measurements was statistically nonsignificant (P=0.077). Conclusion Optical biometry provides longer mean measurements than applanation U/S biometry in eyes with cataract or clear lens, which is represented by a negative difference of 0.05 mm in AEL measurements. These results suggest that applanation A-Scan U/S biometry underestimates AEL.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed88    
    Printed19    
    Emailed0    
    PDF Downloaded27    
    Comments [Add]    

Recommend this journal